"Cross Flow Blowers"
These types of blowers direct airflow perpendicular to the axis of the fan, allowing air to enter from one side of the blower and exit from the other.
Cross-flow blowers are commonly used in applications such as ventilation, heating and cooling systems, and certain household appliances due to their ability to produce a uniform and widespread airflow.
Brief Introduction :
Wheel: Aluminum Alloy Insulation System: Class E, B, F or H as Request
Housing: Galvanized Sheet or E-Coating Operating Temperature: -10°C To +50°C
Motor Type: Shaded Pole Motors NSP61 Series (can be others) Overheating Protection: T.P. or Z.P.
Bearing: Ball Bearing or Bronze Sleeve Electrical Connection: Flat-pin Terminal or Lead Wire
Power Supply: 100 – 240VAC as Request RoHS Compliance: As needed
Technical Performances (tested under room temperature) :
Specs | Power Supply | Input Power | Output Speed | Max. Airflow | Max. Static Pressure | Noise Level | Dimensions(mm) | ||||||||
Volts | Freq’y | Metric | American | Metric | American | A | B | C | D | H | |||||
Model | (VAC) | (Hz) | (Watts) | (rpm) | (m 3 /h) | (CFM) | (Pa) | (in H 2 O) | [dB(A)] | ||||||
① | NAR60120 -SP6120 | 230 | 50 | 17 | 1600 | 70 | 41 | 48 | 0.1930 | 45 | 121 | 132 | 46.5 | 188 | 20 |
120 | 60 | 20 | 2000 | 90 | 53 | 56 | 0.2251 | 49 | |||||||
② | NAR60180 -SP6115 | 230 | 50 | 23 | 1400 | 130 | 77 | 55 | 0.2211 | 45 | 181 | 192 | 77 | 253 | 15 |
120 | 60 | 18 | 1200 | 100 | 60 | 40 | 0.1608 | 40 | |||||||
③ | NAR60240 -SP6125 | 230 | 50 | 33 | 1700 | 170 | 100 | 63 | 0.2533 | 48 | 242 | 253 | 106 | 324 | 25 |
120 | 60 | 30 | 1600 | 160 | 95 | 57 | 0.2291 | 47 | |||||||
④ | NAR60300 -SP6130 | 230 | 50 | 28 | 1400 | 200 | 120 | 45 | 0.1809 | 43 | 303 | 314 | 136 | 380 | 30 |
120 | 60 | 45 | 1600 | 230 | 136 | 60 | 0.2412 | 47 | |||||||
NAR60360 -SP6135 | 230 | 50 | 45 | 1400 | 250 | 148 | 46 | 0.1849 | 44 | 366 | 377 | 166 | 453 | 35 | |
120 | 60 | 47 | 1600 | 290 | 171 | 55 | 0.2211 | 48 |